1. Product Description
MST G+G Pcap (projected capacitive) touch panel, via a process of sputtering an ITO pattern on a glass substrate to make a G-sensor, then laminate 2 layers of glass together, perceive touch accurately via capacitance coupling.
Capacitive touch screen has following outstanding features:
2. Advantages of G+G Structure
(1) High transmittance,>85%.
(2) Hard and anti-wear surface.The hardness is 6H.
(3) Excellent corrosion resistance.
(4) Sensitive touch and stable performance.
3. Basic Features
| Item | Feature | Remarks |
| Controller | ILI2510 | - |
| Channel | TX: 40 RX: 52 | - |
| Power | 5V | USB: 4.7V ~ 6.0V, Typical:5V |
| Communication | USB | USB: 2.0 Full Speed |
| Number of Touch point | 10 | - |
| O.S. | Windows/ Android/ Linux | plug and play |
| Power Consumption | 1.Active Mode: Max.120mA @ USB Input 5V 2.Idle Mode: 90mA @ USB Input 5V 3.Sleep Mode: less than 1mA @ USB Input 5V | |
| Item | Specification | Unit |
| Viewing Area | 345.2(L)×194.6(W) | mm |
| Cover Lense O.D. | 383.2(L)×232.6(W) |
5. Optical Characteristics
| Item | Specification | |
| Transparency | Viewing Area | ≧85% |
| Item | Specification | Unit | ||
| Stacked structure | Cover | 3.0 | mm | |
| LOCA | 0.2 | mm | ||
| ITO | 0.7 |
mm
| ||
| Sensor Glass | ||||
| ITO | ||||
| Sensor Dimension | OD Size | X | 358 | mm |
| Y | 210 | mm | ||
7. Drawing

8. Details

9. Reliablility Test
| Reliability test report | ||||
| Objects | □Raw material □New production process □Abnormal item □New product □Finished product □Sample □Experiment procedure and method □Others □Production line program | |||
| Purpose: to verify the applicability of the experimental product when being stored,transported and used under the extreme environmental conditions. | ||||
| Experiment requirements:
| ||||
| No. | Items | Test condition | Criterion | |
| 1 | High temperature and humidity test | 1. Temperature: 60℃ 2. Humidity: 90%RH 3. Time: finished product 120H | Appearance test refer tostandard OK Function detection OK | |
| 2 | Temperature Switching impact test | 1.High temperature 2.Low temperature 3. 30 times in cycle | Appearance test refer tostandard OK Function detection OK | |
| 3 | Salt spray test | 1.Concentration: 5% NaCl solution 2.Temperature: 35℃ 3.Time: finished product 48H | Appearance test refer tostandard OK Function detection OK | |
| 4 | High temperature storage test | 1.Temperature: 80℃ 2.Time: 120H | Appearance test refer tostandard OK Function detection OK | |
| 5 | Low temperature storage test | 1.Temperature: -30℃ 2.Time: 120H | Appearance test refer tostandard OK Function detection OK | |
| 6 | Red ink test | 1. Room temperature 2. Time: 8H | 1. No ink infiltration 2. All functions are good | |
| 7 | Hand sweat test | 1. Sweat PH=4.7 2. Time: 48H | Appearance test refer tostandard OK Function detection OK | |
| 8 | Static electricity test | 1. Air discharge: 8KV 2. Contact discharge: 6KV 3.Times: 10 times for each point | Appearance test refer tostandard OK Function detection OK | |